Skip to main content
. 2021 Jan 7;6(2):1309–1315. doi: 10.1021/acsomega.0c04754

Table 1. Background of Power Plants and the Mass Concentration of OC and EC in PMsa.

     
stack conditions
emission characteristics
load filtration technology
RH T dust emissions number OC, μg/m3
EC, μg/m3
boiler type and code MW denitration dust remover desulfuration dust remover % K mg/m3 dN/d log Dp PM1.0 PM2.5 PM10 PM1.0 PM2.5 PM10
ULPCB-01 600 SCR ESPs + BFs WFGD WESP 13.9 348 2.1 1.06 × 105 2.01 15.28 17.9 0.19 0.83 0.93
ULPCB-02 330 SCR ESPs + BFs WFGD WESP 9.7 372 4.5 1.19 × 105 1.04 6.31 11.6 0.09 0.75 0.83
ULCFB-01 330 SCR BFs quick lime   3.1 440 3.2 1.97 × 105 2.58 8.32 16.8 0.15 0.41 0.57
ULCFB-02 60 SNCR ESPs quick lime   6.3 427 4.2 3.69 × 105 1.24 4.58 5.64 0.14 1.06 1.85
a

SCR: selective catalytic reduction; SNCR: selective noncatalytic reduction; and BF: bag filter.