Skip to main content
. 2021 Jan 21;11:1946. doi: 10.1038/s41598-021-81479-y

Table 1.

Precision and accuracy for the quantification of C-Man-Trp (CMW) (n = 5).

Nominal Conc. (nM) Mean Conc. (nM) Intra-run Inter-run
Precision (RSD, %) Accuracy RE (%) Precision (RSD, %) Accuracy RE (%)
< 300 nM of CMW (nM)
5 5.64 10.62 19.48 18.34 12.84
10 9.99 8.55 5.27 14.17 − 0.08
25 24.59 6.92 − 2.92 7.98 − 1.63
50 48.70 2.76 − 0.45 5.63 − 2.60
≥ 300 nM of CMW (nM)
5 5.22 9.22 − 2.43 19.86 4.45
10 10.45 11.53 − 3.01 12.71 4.49
25 23.52 7.46 − 9.56 10.95 − 5.94
50 48.36 4.75 − 11.87 7.75 − 3.29