Skip to main content
. 2021 Jan 8;11:607166. doi: 10.3389/fimmu.2020.607166

Table 5.

Performance of salivary morning and evening C-reactive protein (CRP) to identify “systemic inflammation”, defined by the 90th percentile of serum CRP values.

  Sensitivity Specificity Accuracy
Salivary CRP; morning
(n=105)
0.10 (0.11–0.31) 0.89 (0.85–0.91) 0.82 (0.77–0.85)
Salivary CRP; evening
(n=103)
0.22 (0.18–0.43) 0.91 (0.87–0.93) 0.85 (0.81–0.88)

Sensitivity, specificity and accuracy, including 95% confidence intervals (in parentheses) are given.