Skip to main content
. 2021 Jan 8;14(2):306. doi: 10.3390/ma14020306

Table 4.

Results from the measurements of the reinforcement corrosion potential, corrosion current density and resistivity of concrete cover in the load-bearing column, storey II.

Meas. Points Values Meas. Points Values
Est icor Θ Est icor Θ
(1, 1) −18372 0.19 27.50 (2, 1) −316.19 17.53 4.30
(1, 2) −173.89 1.55 13.30 (2, 2) −568.48 6.71 9.90
(1, 3) −169.44 2.47 14.20 (2, 3) −467.14 8.19 6.80
(1, 4) −142.76 2.59 8.80 (2, 4) −437.42 7.28 6.60