Table 6.

Specifications and electrochemical performance of aptasensors for exosomes.

Exosomes Sensor Specification Method Sensing Strategy Sample Matrices Detection Range Limit of Detection (LOD) Ref.
MCF-7 exosomes Apt./2D Ti3C2 MXenes nanosheets Electrogenerated chemiluminescence (ECL) sandwich-type serum 5 × 102–5 × 106 particles μL−1 125 particles μL−1 [137]
hepatocellular exosomes Apt.-nanotetrahedron (NTH) SAM/Au electrode SWV
[Fe(CN)6]−3/−4
sandwich-type membrane proteins 105–1012 exosomes/mL 1 × 104/mL [138]
exosomes exosome transmembrane protein CD63 apt./Au electrode array, microfluidic system SWV
MB redox label
switch-off fetal bovine serum 1 × 108 particles/mL 1 × 106 particles/mL [139]
tumor exosomes LNCaP cells DNAs/Au electrode DPV
Ru(NH3)63−
signal reporter
“turn-off” signal MCF-7 cell, HeLa cell-derived exosomes 1000–120,000 particles/µL 70 particles/µL [140]
Exosomes CD63 apt./GCE/Cu (I)-catalyzed click chemistry DPV
HRP, o-phenylene-diamine (OPD), H2O2
label-free human serum 1.12 × 102 to 1.12 × 108 particles/μL 96 particles/μL [141]
cancer-exosome ITO electrode DPV
DOX redox-active indicator
label-free
“signal-on” strategy
biological, clinical samples 3.4 × 104–3.4 × 108 particles per mL 1.2 × 104 particles per mL [142]
HepG2-exosomes Au electrode/apt. SWV
[Fe(CN)6]−3/−4
displacement reaction serum samples 1 × 105–5 × 107 particles/mL 1.72 × 104 particles/mL [143]
CD63 positive exosomes ITO electrode
microfluidic on-chip platform (ExoPCD-chip)
DPV
[Fe(CN)6]−3/−4, th. enhanced cathodic current
label-free human serum and liver cancer patients, healthy controls 7.61 × 104 particles/mL to 7.61 × 108 particles/mL 4.39 × 103 particles/mL [144]