Skip to main content
. 2021 Jan 13;10(1):105. doi: 10.3390/antiox10010105

Table 3.

Determination of T1/T2, Fe (mg/kg) and Cu (mg/kg) measured by NMR, TXRF and GFAAS, respectively, in selected margarine samples. NMR data are depicted as single measurements. TXRF and GFAAS data are depicted as mean ± SD (n = 3). Statistically significant differences between the margarine samples regarding their Fe and Cu content are indicated with different lowercase letters a and b (one-way ANOVA, Holm–Sidak, p < 0.05).

Margarine Ingredients T1/T2 Fe (mg/kg) Cu (mg/kg)
M1 E1, SC 1 2.67 2.88 ± 0.85 a 0.10 ± 0.01 a
M8 M1 + aTA, −20% 1.47 3.08 ± 0.56 a 0.06 ± 0.01 b
M11 M1 + RE, −20% 3.81 4.64 ± 0.31 b 0.06 ± 0.01 ab
M14 M1 + GTE, −20% 33.2 2.22 ± 0.26 a 0.09 ± 0.01 ab
M(total) M14 + minor ingredients 3.58 3.42 ± 0.33 ab 0.06 ± 0.01 ab

1 SC=standard concentration/commonly applied concentration.