Skip to main content
. 2021 Jan 14;14(2):390. doi: 10.3390/ma14020390

Table 4.

Tensile parameters for impact testing.

Ref. Data Tensile Parameters Maximum Tensile Strength (MPa) Tensile Toughness (MPa × 10−3)
E (MPa) εcr ( με ) μ β tu
TRC-AAC
Drop height 75 mm 162 2080 0 24 0.34 3.2
Drop height 150 mm 148 2080 0 43 0.31 8.0
Drop height 300 mm 148 2080 0 63 0.31 10.0
TRC-FRAC
Drop height 75 mm 162 2080 0.33 30 0.33 15.8
Drop height 150 mm 175 2080 0.33 40 0.36 20.7
Drop height 300 mm 202 2080 0.33 50 0.42 29.8