Skip to main content
. 2021 Jan 14;21(2):557. doi: 10.3390/s21020557

Table 7.

Fully charging time ta in a network branch with ten sensor nodes in terms of the voltage amplitude Vin of the applied sinusoidal charging tone.

Vin ID ton ton + ttr trun tstable
24 Vpp 1 0.177 0.385 24.675 23.560
2 0.222 0.457 24.619 23.478
3 0.289 0.520 24.538 23.400
4 0.385 0.615 24.427 23.291
5 0.534 0.770 24.265 23.122
6 0.752 1.010 24.025 22.861
7 1.100 1.376 23.657 22.476
8 1.645 2.273 23.100 21.566
9 2.568 4.844 18.989 15.801
10 TOR N27 TOR N27
18 Vpp 1 0.231 0.433 24.606 23.498
2 0.289 0.515 24.536 23.404
3 0.372 0.607 24.439 23.298
4 0.559 0.739 24.237 23.152
5 0.714 0.929 24.070 22.948
6 1.020 1.249 23.740 22.605
7 1.504 1.982 23.241 21.854
8 2.316 3.799 20.083 17.697
9 3.703 N27 16.365 N27
10 TOR N27 TOR N27
10 Vpp 1 0.335 0.546 24.475 23.358
2 0.440 0.683 24.358 23.208
3 0.604 0.854 24.180 23.022
4 0.872 1.121 23.896 22.742
5 1.305 1.687 23.451 22.160
6 1.990 2.912 22.275 20.449
7 3.145 N27 17.617 N27
8 TOR N27 TOR N27
9 TOR N27 TOR N27
10
5 Vpp 1 0.559 0.790 24.210 23.072
2 0.791 1.042 23.965 22.806
3 1.178 1.525 23.563 22.311
4 1.855 2.955 22.190 20.184
5 3.118 N27 17.183 N27
6 TOR N27 TOR N27
7 TOR N27 TOR N27
8
9
10

N27: 2.7V no reached in ta + tb = 20 ms. TOR: Turn on and off repeatedly. —: Never turn on.