Skip to main content
. 2021 Jan 15;21(2):591. doi: 10.3390/s21020591

Table 5.

Relative errors and UQI of image reconstruction results from the male phantom using each set of hyperparameters and the CGLS algorithm [15].

Sets of Hyperparameter/Method Relative Error (%) UQI ε ng
Proposed method from the training dataset 8.26 0.9946 2000 10
Proposed method with the male phantom 5.33 0.9980 70 22
Cross-validation from the training dataset 10.63 0.9909 0 8
Arbitrary setting 12.78 0.9863 700 100
CGLS 15.94 0.9798 N/A N/A