Skip to main content
. 2020 Dec 24;194:110665. doi: 10.1016/j.envres.2020.110665

Table 1.

List of various instruments used for obtaining different atmospheric parameter measurements used in this study.

Instrument Parameters Measured Lower detection limit Uncertainty range Mesauremnt period (Data Availability) Reference for further details on instrumentation
Trace Gas Analysers
APOA 370
APNA 370
APMA 370
APSA 370
Horiba, Japan
O3
NO, NO2, NOX
CO
SO2
0.5 ppbv
0.5 ppbv
20 ppbv
0.5 ppbv
±5.0% 1-Feb to 31-May (2019 and 2020) Horiba (2020)
Picarro CRDS Analyzer
G2401
Picarro INC, USA
CO
CO2
CH4
15 ppbv
50 ppbv
1 ppbv
±2.0% 1-Feb to 31-May (2019 and 2020) Picarro (2020)
PM sensor
Plantower PMS 7003
Beijing Plantower Co. Ltd.
PM1, PM2.5 and PM10 ±10–15 μg/m3 ±10% 1-Feb to 31-May (2020) Zheng et al. (2018)
Aethalometer
AE31
Magee Scientific USA
Black Carbon (BC) 0.1 μg/m3 ±5.5% 1-Feb to 31-May (2019 and 2020) Hansen (2005)
Sky Radiometer
POM-01L
Prede Co. Ltd, Japan
AOD NA ±5.5% 1-Feb to 31-May (2019 and 2020) Prede (2020)
Pyranometer
CMP22
Kipp&Zonen, Netherlands
Global Horizontal Irradiation (GHI) and Diffuse Horizontal Irradiance (DHI) NA ±1.5% 1-Feb to 31-May (2019 and 2020) Kipp and Zonen (2020)