Skip to main content
. 2020 Dec 9;126(3):590–598. doi: 10.1016/j.bja.2020.12.010

Table 3.

ClotPro analysis of critically ill COVID-19 patients with decreased fibrinolytic response compared with critically ill COVID-19 patients with normal fibrinolytic response.

Total (n=20) TPA LT ≤393 s (n=6) TPA LT >393 s (n=14) Estimate with 95% CIa P-valueb Not known
TPA test
 CT (s) 49.5 (41.5–90.2) 73.5 (46.5–109.5) 47.5 (40.5–84.25) 12 (–19 to 66) 0.27 0/0
 LT (s) 508 (364.75–826.75) 321.5 (278.75–347) 573 (503–982) –296.5 (–688 to –160) <0.01 0/0
 MCF (mm) 55 (38.75–64) 34 (27.5–43.5) 62 (55–64.75) –22.98 (–36 to –10) <0.01 0/0
 ML (%) 97 (95–98) 95.5 (95–96.75) 97 (96.25–98) –1 (–3 to 0) <0.01 0/0
EX test
 CT (s) 51.5 (46.75–76.25) 72 (46.25–106) 51.5 (47–65.5) 13.49 (–15 to 62) 0.59 0/0
 A5 (mm) 58 (50–61) 49 (47.25–52.25) 59.5 (57.25–64) –10 (–15 to –3) 0.01 0/0
 A10 (mm) 65.5 (58–67.5) 56.5 (55–59.5) 66 (64.5–69) –9 (–14 to –3) <0.01 0/0
 A20 (mm) 67.5 (62–70.25) 60 (57.25–62.75) 69.5 (67.25–71.75) –8.9 (–13 to –3) <0.01 0/0
 MCF (mm) 68.5 (62.75–71.25) 60 (57.25–62.75) 70.5 (68.25–72) –9 (–14 to –4) <0.01 0/0
 ML (%) 3 (2–7) 7.5 (4.75–8.75) 2 (1–3) 4.6 (1–7) <0.01 0/1
IN test
 CT (s) 188 (167.75–214.75) 203 (183.75–250) 180 (164–208.25) 23 (–18 to 71) 0.11 0/0
 A5 (mm) 52.5 (44–56.75) 44 (41.75–45.5) 54.5 (51.5–59) –10.75 (–15 to –3) 0.01 0/0
 A10 (mm) 60.5 (53–64.5) 53 (50–54.5) 62 (60.25–66) –9 (–14 to –3) 0.01 0/0
 A20 (mm) 64.5 (58–68.25) 57.5 (54–58.75) 66.5 (64.25–69) –9 (–13 to –4) <0.01 0/0
 MCF (mm) 64.5 (59–69) 58 (54–59) 66.5 (64.25–69) –9.99 (–14 to –3) <0.01 0/0
 ML (%) 4 (3–8) 7.5 (4.75–9.5) 3 (2–4) 4 (0–7) 0.04 0/3
FIB test
 CT (s) 72 (53–108) 94 (64–119) 66 (52–104) 15 (–18 to 61) 0.28 0/0
 A5 (mm) 29 (23–32) 22 (18–25) 32 (28–34) –10 (–15 to –3) <0.01 0/0
 A10 (mm) 31 (25–35) 24 (20–27.25) 34 (31–36.5) –10 (–16 to –4) <0.01 0/0
 A20 (mm) 33 (27–37) 25 (22–28) 36 (32–38) –11 (–16 to –4) <0.01 0/0
 MCF (mm) 34 (28–39) 26 (24–30) 38 (34–40) –11 (–17 to –4) <0.01 0/0

Continuous data as medians (25th to 75th percentile).

A5, amplitude after 5 min; A10, amplitude after 10 min; A20, amplitude after 20 min; CI, confidence interval; CT, clotting time; LT, lysis time; MCF, maximal clot firmness; ML, maximum lysis; TPA LT, lysis time in TPA test.

a

Odds ratios for binary variables and estimated median difference for continuous variables (CI).

b

Assessed with Fisher's exact test for categorical variables and the Wilcoxon rank sum test for continuous variables.