Table 3.
Procedure category (no of studies) | Procedures investigated (e.g. cavity preparation) and type of investigation (clinical/ laboratory, patient/ mannequin) | Investigated contamination of operator, assistant, patient | Area within dental surgery investigated* | Different timepoints sampled (hours, minutes, seconds) | Detection sensitivity scores for outcome methodologies |
---|---|---|---|---|---|
USS (n=44)a | Ultrasonic scaling (n=44) | Operator (n=18) 5,8,9,10,16,21,31,44,45,55,59,60,63, 65,70,72,83,85 | Environmental surfaces < 1m (n=15) 8,16,21,33,37,45,52,54,61,66,71,73,74,76,78) | During procedure (n=28) 8,9,22,23,24,25,32,48,90,52,54,59,60,61,62,64,65,66,69, 70,72, 73,74,76,78,80,85,87 | High detection sensitivity (n=5) |
Simulation Mannequin (n=3)8,25,83 | Head/face (n=13)8,9,10,16,21,31,44,53,59,65,72,83,85 | >1m (n=3)25,44,64 | During and after combined (n=8) 10,16,21,31,41,44,45, 71 | Moderate detection sensitivity (n=3) | |
Simulation Typodont Laboratory (n=3)33,34,66 | Body (n=8)5,8,10,31,60,70,83,85 | < 1m and > 1m (n=9) 10,41,48,69,90,70,80,83,87 | After procedure(n=3) | Low detection sensitivity | |
Assistant (n=4) | Air Samples (n=7)6,22,23,24,29,32,87 | 0–30 min29,37,83 | (n=34) | ||
Head (n=2)16,83 | 30 min-1 hr29,37,83 | Uncategorized detection sensitivity (n=2) | |||
Body (n=3)31,70,83 | 1–2 hr29,83 | ||||
Patient (n=14) | 2–4 hr29 | ||||
Chest (n=14)5,8,16,21,31,44,60,61 62,65,70,71,73,85 | |||||
HSAR (n= 31)b | Tooth/cavity preparation (clinic) (n= 24) | Operator (n=10) | Using settle plate within 1m of operating area | Within the first 30 minutes after the procedure (n=4)8, 29,51, 94 | High detection sensitivity (n=4) |
Mannequin/ Typodont (clinic) (n=3)8,36,42 | Head/face (n=9)96,95, 20,8,81,59,63,55,3, Body (n=2)8,60 | (n=12)93,8,92,42,48,59,63,90,60,81,94,87 | Between (30 min -1 hr) after procedure (n=2)29,51 | Moderate detection sensitivity (n=6) | |
Mannequin/ typodont simulation (laboratory) (n=4)13,30,51,89 | Assistant (n=3) | Using settle plate 1m or more from operating area (n=9)93,48,90,56,63,94, 60,63, 81 | 1-2 hr (n=2)29,51, 2-4 hr (n=2)29,51, > 4 hr (n=1)51 | Low detection sensitivity (n=21) | |
Head/face (n=3)8,81,63, Body (n=1)8 | |||||
Patient (n=6) | |||||
Intra-oral (n=1)20, Head/face (n=1)95, Body (n=4)92, 20, 8, 94 | |||||
Oral surgery (including extractions) (n=11)c | Surgical removal of teeth (clinic) (n=8) 4, 17, 38,39,84, 43, 87, 98 | Operator (n=5) | Environment and surfaces within 1m from operating area (n=4) 17,32, 39, 46, 87 | Up to 30 min during procedure (n=2)17,43 | High detection sensitivity (n=3) |
Head/ face/neck (n=4) 4, 38, 40, 98 | |||||
Implants (clinic) (n= 1) 98 | Arms/ Cuffs/ hands | Environment and surfaces 1m or more from | During treatment with agar plates replaced every 10 min (n=1)32 | Moderate detection sensitivity (n=2) | |
Extraction (clinic) (n=2) 32,98 | (n= 3) 4, 38, 40 | operating area (n=0) | Low detection sensitivity (n=6) | ||
Other: restorative and periodontal procedures (clinic) (n=1) 87 | Abdomen/ shoes (n= 3) 4, 38, 4 | Sampled at mouth (n=0) | |||
Nearby operator (n=1) 43 | |||||
Assistant (n=3) | |||||
Head/ face/neck (n=2) 4, 98 | |||||
Not verified/ unclear (clinic) (n=2) 40, 46 | Arms/ Cuffs/ hands, (n=1) 4 | ||||
Other body parts (n=1) 4 | |||||
Nearby assistant (n=1) 43 | |||||
Patient: (n=3) | |||||
Head/ face, (n=1)4 | |||||
Chest (n=2)4, 17, 43 | |||||
Slow-speed handpiece (n=5)d | Removal of excess material following fixed orthodontic appliance removal (n=3)14,15,97 | Operator (n=1)2 (thorax and abdomen area of technician) | Air sampler 30cm from patient’s mouth (n=2)14,15 | Not specified (n=5) | High detection sensitivity (n=3) |
Air sampler 10cm from patient’s mouth (n=1)97 | Moderate detection sensitivity (n=0) | ||||
Polishing and trimming of denture (n=2)2,47 | Settle plates at 1ft, 2ft and 3ft from the motor n=147 | Low detection sensitivity (n=2) | |||
Air-water syringe (n=4)e | Air-water syringe with air and water used together (n=3)89,90,95 | N/A | Experimental Simulation-Air Samples Human aerosol test chamber89 | During procedure (n=3)89,90,93 | High detection sensitivity (n=0) |
After procedure (n=1)51: at 2 min, 35 min, 2 hr, 4 hr and 6 hr. | |||||
Air-water syringe with air alone (n=4)51,89, 90,93 | Quartz crystal microbalance cascade impactor (QCMCI)95 | Moderate detection sensitivity (n=1) | |||
Air-water syringe with water alone (n=4)51,89, 90,93 | Clinical (splatter plate) 90,91 | Low detection sensitivity (n=3) | |||
0–1m90,91 | |||||
1–2m90,91 | |||||
Air polishing (n=4)f | Air polishing (clinic) (n=3)18,49,53 | Operator | Air sampled 12 inches from patients’ mouth at 50o angle53 | 30 min including procedure of 2 min49,53 | High detection sensitivity (n=0) |
Head/face (n=3)18,49,53 | |||||
Mannequin/ typodont simulation (laboratory) (n=1)35 | Patient | Air sampled < 1m of operating area35 | During procedure (n=2)18,35 | Moderate detection sensitivity (n=1) | |
Body (n=1)18 | Surface < 1m operating area (n=1)49 | Low detection sensitivity (n=3) | |||
Surface > 1 m (n=1)49 | |||||
Prophy: cup and pumice (n=2)g | Prophy on patient’s head in closed experimental test chamber with side glove ports (clinic) (n=1)89 | N/A | Air sampling of the closed chamber around the patient’s head89 | During the procedure (10–120 sec) with 4 min clearance period of quiet breathing before and after89 | High detection sensitivity (n=0) |
Prophy (clinic) (n=1)90 | Air sampled 3 ft from floor and 1 ft from patients’ mouth (in front) to the sides and end of the surgery90 | During procedure (30 sec)90 | Moderate detection sensitivity (n=0) | ||
Low detection sensitivity (n=2) | |||||
Hand scaling (n=2)h | Hand scaling patient head in closed test chamber with side glove ports (clinic) (n=1)89 | N/A | Air sampling of the closed chamber around the patient’s head89 | During procedure (10–120 sec) with 4 mins clearance period of quiet breathing before and afterwards89 | High detection sensitivity (n=0) |
Moderate detection sensitivity (n=0) | |||||
Mannequin/typodont simulation (laboratory) (n=1)34 | Air sampled around mouth distance not specified34 | During procedure (2 sec)34 | Low detection sensitivity sampling/measuring approach (n=3) |
Unique study identification numbers.
Dos Santos 201418, Harrel 199935, Logothetis 199549, Muzzin 199953.
m = metre(s); ft – foot/feet; in = inch(es); cm = centimetre(s); hr = hour(s); min = minute(s); sec = second(s).
Balcos 20195, Barnes 19986, Bentley 19948, Choi 20189, Chuang 201410, Devker 201216, Feres 201021, Fine 199222, Fine 1993 a23, Fine 1993b24, Graetz 201425, Grenier 199529, Gupta 201431, Hallier 201032, Harrel 199834, Harrel 199633, Holloman 201537, Jawade 201641, Kaur 201444, King 199745, Labaf 201148, Miller 197190, Mohan 201652, Narayana 201654, Nejatidanesh 201355, Prospero 200359, Purohit 200960, Ramesh 201561, Rao 201562, Reddy 201264, Retamal-Valdes 201765, Rivera-Hidalho 199966, Sadun 202069, Saini 201570, Sawhney 201571, Serban 201372, Sethi 201973, Shetty 201374, Singh 201676, Swaminathan 201478, Timmerman 200480, Veena 201583, Watanabe 201385, Yamada 201187.
Al-Amad 20173, Belting 196393, Bentley 19948, Cochrane 198992, Dahlke 201213, Day 200815, Earnest20, Greco 200828, Grenier 199529, Grundy 196730, Hallier 201032, Hausler 196636, Junevičius 200542, Labaf 201148, Larato 196691, Manarte-Monteiro 201350, Micik 196989, Miller 197190, Miller 199551, Neiatidanesh 201355, Oliveira 201856, Prospero 200359, Purohit 200960, Rautemaa 200663, Samaranayake 198988, Stevens 196396, Tag El-Din 199794, Toroğlu 200181, Toroğlu 20038, Travaglini95, Yamada 201187.
Al-Eid 20184, Divya 201917, Hallier 201032, Ishiharma 200838, Ishiharma 200939, Janani 201840, Jimson 201543, Kobza 201846, Wada 201084, Yamada 201187, Aguilar-Duran 202098.
Agostinho 20042, Dawson 201614, Day 200815, Ireland 200397, Kritivasan 201947.
Belting 196393,, Micik 196989, Miller 197190, Miller 199551.
Micik 196989, Miller 19719.
Harrel 199834, Micik 196989.