Skip to main content
. 2021 Jan 15;141:155428. doi: 10.1016/j.cyto.2021.155428

Table 3.

Area under the ROC curve and optimal cut-off values of the immune inflammatory markers according to the severity.

Variable AUROC Optimal cut-off value Sensitivity Specificity OR (95%CI)
NLR 0.831 5.9 71.7% 80.3% 8.7 (3.85–19.7)
d-NLR 0.748 4.6 57% 87% 7.95 (3.36–18.83)
WBC 0.693 9.67 × 103/µl 63% 83.1% 8.11 (3.53–18.66)
NEU 0.765 8.84 × 103/µl 55% 93% 15.95 (5.54–45.94)
LYM 0.737 0.9 × 103/µl 51% 88.7% 8.30 (3.34–20.66)
IL6 0.972 44 pg/ml 94.9% 93.2% 253.86 (58.11–1109)
PCT 0.856 0.138 ng/ml 76.3% 79.5% 12.42 (5.44–28.39)
CRP 0.816 123 mg/l 70% 80.8% 9.59 (4.29–21.45)
Ferritin 0.752 601 ng/ml 83.1% 64.4% 8.86 (3.85–20.35)
IL2Rα 0.724 1204 U/ml 54.2% 83.6% 6.02 (2.69–13.45)
IL6 + NLR 0.98

The optimal discriminating cut-off values were obtained by calculating the Youden index. The Odds Ratio with their confidence intervals 95% were calculated according to the cut-off values by Fisher's exact test.