Table 2.

Aerosol particle concentrations (#/m3, Mean ± SD) before and after 5 min of incense burn and after 30 min of observation with ventilation off but portable air cleaner on.

0.3 μm 0.5 μm 1.0 μm Total
Baseline 1.0 × 107 ± 6.4 × 106 8.8 × 105 ± 5.9 × 105 1.3 × 105 ± 6.6 × 104 1.1 × 107 ± 7.0 × 106
After incense burn 6.3 × 107 ± 1.3 × 107 1.7 × 107 ± 1.2 × 107 4.6 × 105 ± 2.2 × 105 8.0 × 107 ± 2.4 × 107
Aerosol accumulated (Qe) 5.2 × 107 ± 1.3 × 107 1.6 × 107 ± 1.1 × 107 3.2 × 105 ±2.5 × 105 6.9 × 107 ± 2.2 × 107
After 30 min 9.6 × 105 ± 4.8 × 105 7.9 × 104 ± 3.6 × 104 1.9 × 104 ± 1.7 × 104 1.0 × 106 ± 5.0 × 105
% Aerosol removed* 119.0 ± 13.2 108.3 ± 9.2 150.5 ± 34.7 116 ± 11
*

Aerosol concentrations were lower than the baseline after 30-min, indicating that the portable air cleaner removed all the aerosol particles accumulated from incense burn and some particles already existed in the room at baseline.