Table 2.
0.3 μm | 0.5 μm | 1.0 μm | Total | |
---|---|---|---|---|
Baseline | 1.0 × 107 ± 6.4 × 106 | 8.8 × 105 ± 5.9 × 105 | 1.3 × 105 ± 6.6 × 104 | 1.1 × 107 ± 7.0 × 106 |
After incense burn | 6.3 × 107 ± 1.3 × 107 | 1.7 × 107 ± 1.2 × 107 | 4.6 × 105 ± 2.2 × 105 | 8.0 × 107 ± 2.4 × 107 |
Aerosol accumulated (Qe) | 5.2 × 107 ± 1.3 × 107 | 1.6 × 107 ± 1.1 × 107 | 3.2 × 105 ±2.5 × 105 | 6.9 × 107 ± 2.2 × 107 |
After 30 min | 9.6 × 105 ± 4.8 × 105 | 7.9 × 104 ± 3.6 × 104 | 1.9 × 104 ± 1.7 × 104 | 1.0 × 106 ± 5.0 × 105 |
% Aerosol removed* | 119.0 ± 13.2 | 108.3 ± 9.2 | 150.5 ± 34.7 | 116 ± 11 |
Aerosol concentrations were lower than the baseline after 30-min, indicating that the portable air cleaner removed all the aerosol particles accumulated from incense burn and some particles already existed in the room at baseline.