Skip to main content
. 2020 Dec 10;8(1):47–54. doi: 10.1002/ehf2.13167

Table 3.

Peak VO2 (mean, median, standard deviation, mean difference, and standard error in mL/kg/min) and correlational values from cardiopulmonary exercise and predicted by New York Heart Association functional class using Cahalin et al. 21 equation

NYHA Method Mean Median SD Mean difference (standard error) Correlation (r)
Class I and II (n = 76) CPX 17.5 17.7 3.5 0.22 (0.27) 0.63*
Cahalin equation 17.3 17.4 2.5
Class III (n = 30) CPX 13.8 14.4 3.5 −0.86 (0.3) 0.67*
Cahalin equation 14.48 14.63 2.7
*

A significant correlation between actual CPX testing VO2 peak and predicted VO2 peak values at P = 0.05.