Skip to main content
. 2020 Sep 25;35(1):35–42. doi: 10.1007/s00540-020-02856-x

Table 2 .

Changes in each variable in EXTEM

EXTEM Reference range [11] 0 4 h 8 h 12 h 24 h
CT, s 42–74 67 ± 6 55 ± 5 61 ± 7 60 ± 3 64 ± 6
CFT, s 46–148 111 ± 5 121 ± 11 133 ± 9 120 ± 9 141 ± 7**
MCF, mm 49–71 62 ± 1 61 ± 1 58 ± 1*** 56 ± 2* 55 ± 1***

MCE,

(G dynes/cm2)/50

105–235 167 ± 6 155 ± 4 139 ± 6*** 131 ± 10* 121 ± 5***

Mean ± SEM

CT clotting time CFT clot formation time, MCF maximum clot firmness, MCE maximal clot elasticity;

*p < 0.05, **p < 0.01, ***p < 0.001vs. 0