Skip to main content
. 2020 Feb 11;27(Pt 2):305–318. doi: 10.1107/S1600577519017235

Table 1. Summary of the main parameters from the metrology of the Be lenses used in the simulations.

The bottom rows display the accumulated figure errors calculated by propagating a plane wave through the system; the accumulated figure errors weighted with the system transmission at 8 keV; and the quadrature summation of the individual r.m.s. values from L01 to L10.

    Figure errors (r.m.s) (µm)  
Lens number Radius (µm) FF LF HF Useful aperture (µm)
L01 49.43 0.56 0.47 0.30 425.9
L02 48.66 1.12 1.03 0.42 421.0
L03 49.18 0.90 0.74 0.52 430.9
L04 49.88 2.24 2.18 0.49 427.2
L05 48.66 1.19 1.07 0.52 424.7
L06 49.26 1.15 0.85 0.77 428.4
L07 49.29 0.75 0.60 0.46 433.4
L08 49.41 1.28 1.13 0.69 432.1
L09 48.71 1.43 1.36 0.44 433.3
L10 48.63 0.82 0.73 0.37 417.3
 
Accumulated 5.22 4.91 1.77 417.3
Weighted 3.64 3.54 0.85
Quadrature-sum 3.88 3.53 1.63