Table 3. Comparison of ROBL-II with other dedicated radionuclide beamlines.

  ROBL-II INE-KARA ACT-KARA Mars-SOLEIL microXAS-SLS
Reference This paper (Rothe et al., 2012) (Zimina et al., 2016, 2017) (Llorens et al., 2014; Sitaud et al., 2012) (Borca et al., 2009)
Source SBM (0.6 T) on 6 GeV ring at 200 mA BM (1.6 T) on 2.5 GeV ring at 200 mA Superconducting 2.5 T wiggler on 2.5 GeV ring at 200 mA BM (1.7 T) on 2.75 GeV ring at 500 mA Minigap in-vacuum undulator
Photon flux 6 × 1012 ph/s at 20 keV and 200 mA 2 × 1010 ph/s at 18 keV 1011 ph/s at 20 keV and 100 mA 1 × 1012 ph/s at 12 keV and 430 mA 3 × 1012 ph/s at 12 keV
Mirror 1 VCM (Si, Rh, Pt) at 2.5 mrad VCM (Rh) at 2.7 mrad) VCM (Si, Rh, Pt), mirror-less VCM (Si, Pt) Horizontally deflecting toroid (Rh)
DCM Si(111), Si(111)30°, Si(311) multilayer Si(111), Si(311), Ge(422), InSb(111) Si(111), Si(311) Si(111) and Si(220) on sagittal bender for horizontal focusing Si(111), Si(311), Ge(111)
Mirror 2 Double-toroid (Rh, Pt), VFM§ (Si) Toroid (Rh) Double-toroid (Si, Rh), VFM (Ir), mirror-less VFM (Si, Pt) Elliptical Kirkpatrick–Baez (KB) (Rh)
Energy range (keV) 3.5–35 2.1–25 3.4–55 3.5–35 4–23
Spot size on sample (h × v) (µm) 21 × 69 (focused) 10000 × 2000 (unfocused) 500 × 500 1000 × 1000 (focused) 300 × 300 15 × 15 (with additional KB optics) 1.0 × 1.0 with 1011 ph/s dynamic focusing
Maximum activity 185 MBq Exemption limit ×106 for non-fissile isotopes, 200 mg for fissile 235U and 239Pu 185 GBq, 18.5 GBq per sample 100 × LL per sample (Swiss clearance limit) maximum 10 samples
Maximum dose rate 0.5 µSv h−1 outside of glovebox, 15 µSv h−1 in contact with sample confinement None, as long as the annual dose rate of 6 mSv for controlled areas is respected <0.5 µSv h−1 outside the beamline, <2 mSv h−1 inside the beamline 0.5 µSv h−1 outside of hutch, 2 mSv h−1 in experimental hutch
Experimental stations (A) EXAFS with 18-element Ge (Mirion) and Falcon-X (XIA) (B) Spectrometer (Johann-type, five-crystal, 0.5 and 1 m Rowland circle) (C) Six-circle diffractometer (LaB6 (110: 0.013°FWHM) (D) Pilatus diffractometer EXAFS with Vortex ME4 and Vortex EX60 (Hitachi), xMAP-DXP (XIA) Spectrometer (Johann-type, 5-bent-crystals, 1 m Rowland circle) with Si(Li) SDD (Ketek) and Vortex EX60 or EXAFS with 8-element HPGe array detector (Mirion), xMAP-DXP (XIA) (A) High-resolution XRD (B) EXAFS with 13-element Ge (ORTEC) and DXP-xMAP or 13-element SDD (MIRION) with Xspress 3 (Quantum) or Spectrometer (Johann-type, 4-crystal 0.5 m, and 1-crystal 1 m), Image plate (MAR345) or Hybrid pixel CdTe (Pilatus /DECTRIS) for 2DXRD and SAXS (A) Micro-XAS with 1-element (Ketek) and 5-element (SGX) SDD, Falcon-X (XIA), Eiger 4M area detector or Spectrometer (von Hamos)
In operation since 1998 (ROBL), 2020 (ROBL-II) 2005 2017 2009–2010 (below exemption limit), 2013 2006–2007
User access Public user facility (33%), inhouse and collaborations (67%) Inhouse and collaborations Public user facility (47%), CEA dedicated time (33%), inhouse (20%) Public user facility

VCM: vertical collimating mirror.

Vertical collimation and dynamic focusing in horizontal.

§

VFM: vertical focusing mirror.