Skip to main content
. 2021 Jan 28;11:2480. doi: 10.1038/s41598-021-82281-6

Table 5.

Results of ROC analyses for the N200 and P300 ERP components.

ERP Cut point values Specificity Sensitivity Accuracy
Latency (ms)
N200 Fz 225 0.84 0.67 0.82
Cz 224 0.84 0.66 0.82
Pz 221 0.84 0.67 0.82
P300 Fz 343 0.86 0.71 0.82
Cz 344 0.91 0.67 0.82
Pz 349 0.91 0.57 0.81
Amplitude (uV)
P300 Fz 4.71 0.8 0.57 0.71
Cz 5.23 0.77 0.66 0.73
Pz 5.32 0.82 0.66 0.75

ERP event-related potential, Fz frontal region, Cz central region, Pz parietal region.