Skip to main content
. 2021 Jan 26;9:e10623. doi: 10.7717/peerj.10623

Table 2. Segment angle ROM mean and standard deviation.

ROM data (mean ± SD) for motion capture (mocap) and inertial sensors (IMU) for 11 participants (five for cervical flexion/extension). Segment angles are reported for all spinal segments (S1, L1, T6, T1 and SK). The movements from left to right were flexion, extension, lateral flexion, cervical rotation, and cervical flexion/extension.

Flex Ext Lat Flex Cer Rot Cer F/E
S1 mocap 62.3 ± 13.9° 9.6 ± 6.0° 7.6 ± 2.2°
IMU 60.5 ± 13.7° 9.4 ± 5.8° 7.6 ± 2.3°
L1 mocap 110.8 ± 13.3° 24.7 ± 11.1° 31.2 ± 5.2°
IMU 111.0 ± 13.2° 24.8 ± 11.3° 30.9 ± 4.9°
T6 mocap 125.4 ± 11.2° 32.5 ± 10.4° 45.9 ± 7.6°
IMU 125.5 ± 11.0° 32.4 ± 10.5° 47.3 ± 7.9°
T1 mocap 107.4 ± 11.2° 43.4 ± 9.7° 52.1 ± 9.9°
IMU 107.9 ± 11.3° 43.7 ± 9.8° 53.8 ± 10.1°
SK mocap 73.5 ± 10.2° 123.7 ± 14.9°
IMU 73.4 ± 10.1° 124.1 ± 14.2°