Finite element simulation results under different experimental conditions.

Experimental conditions 20 mm-45°-16 μm (This work) 10 mm-90°-30 μm (Predicted)
Amplitude, μm 5 11.6
Ultrasonic intensity, W/cm2 355 1987
Average ultrasonic pressure amplitude, MPa 0.125 0.39