Skip to main content
. 2021 Feb 2;51(5):3026–3043. doi: 10.1007/s10489-020-01978-9

Table 9.

Performance of Corona-Nidaan on the ChestX test dataset

Precision Recall F1-Score
COVID-19 0.94 0.94 0.94
Normal 0.93 0.98 0.96
Pneumonia 0.97 0.92 0.94
Accuracy 0.95
Macro avg 0.95 0.95 0.95
Weighted avg 0.95 0.95 0.95