Skip to main content
. 2019 Jun 5;9(11):e3253. doi: 10.21769/BioProtoc.3253

Table 3. Inner filter effect data processing for haem.

[Haem] μM 0 0.3984 0.7936 1.3807 2.15264 3.68932 5.60928 7.52895 11.3462 17.0172 36.0687
Fluorescence intensities at top 5 wavelengths 720.154 697.296 656.790 644.240 619.960 576.750 536.299 495.699 428.407 350.978 178.493
731.785 695.609 662.792 642.030 613.975 576.054 536.828 494.665 432.185 354.062 179.209
724.467 693.689 664.013 638.424 617.182 579.671 536.130 497.589 431.487 353.565 180.623
718.830 691.224 659.906 642.552 612.479 576.233 531.706 489.314 428.199 350.630 179.322
725.489 692.393 665.459 638.383 611.570 577.338 531.688 495.957 431.974 354.534 178.990
Average Intensity 724.145 694.042 661.792 641.126 615.033 577.209 534.531 494.645 430.450 352.754 179.327
Difference from expected Fl intensity 0.000 -30.103 -62.353 -83.019 -109.112 -146.936 -189.615 -229.500 -293.695 -371.392 -544.818
% difference from inner filter effect 0.000 -4.157 -8.611 -11.464 -15.068 -20.291 -26.185 -31.693 -40.557 -51.287 -75.236
Corrected Fl Intensity 724.145 724.145 724.145 724.145 724.145 724.145 724.145 724.145 724.145 724.145 724.145
Fluorescence scaled /1 1.000 0.958 0.914 0.885 0.849 0.797 0.738 0.683 0.594 0.487 0.248