Table 2.

Parameters and correlation coefficients of adsorption isotherms according to Langmuir and Freundlich

Metal Sorbents Langmuir
Sorbents Freundlich
Qmax (g/kg) Kd r2 1/n Kf r2


As MAC 0.425 4.96E4 0.86 APM 0.64 2.22 0.97


Cd MAC 0.63 2.0E4 0.88 APM 0.76 4.24 0.98


Hg MAC 7.97 7.28E4 0.91 APM 0.9 46.76 0.86


Pb APM 5.98 3.69E4 0.95 MAC 1.08 119.9 0.85

Qmax, binding capacity; Kd, binding affinity; r2, correlation coefficients; 1/n, degree of heterogenicity; Kf, Freundlich distribution constant