Skip to main content
. Author manuscript; available in PMC: 2022 Feb 1.
Published in final edited form as: IEEE Trans Biomed Eng. 2021 Jan 20;68(2):448–460. doi: 10.1109/TBME.2020.3004310

TABLE IV.

Classification Performance On Armband Data

Subject ID No of seg. Accuracy (%)
SVM 79 feat. SVM 9 feat. RF 79 feat. RF 9 feat. Stat. Method [6]
AF #1 50 76 88 86 86 100
AF #2 14 100 92.86 64.29 100 100
PAC #1 55 100 100 100 100 85.45
PAC #2 55 100 100 100 100 96.36
PAC #3 10 100 100 100 100 100
PAC #4 30 100 100 100 100 96.67
PAC #5 50 100 100 100 100 100
Mean Total=264 96.57 97.27 92.9 98 96.93