Input parameters of the examined RCbeams.

Beam Name Ε (GPa) ν Gf (N/mm) ft
(MPa)
εt0
(‰)
w1
(mm)
wu
(mm)
dt1 dt2
FLM 30.85 0.2 0.03 2.42 0.078 0.00827 0.02481 0.4 0.9