Table 6.
Sensor(s) | Source | Accuracy | Precision | Sensitivity | Specificity |
---|---|---|---|---|---|
Infrared fence | [38] | N/A | N/A | 85.3% | 96.2% |
Pressure mat | [38] | N/A | N/A | 90.4% | 99.3% |
Pressure sensor | [39] | N/A | N/A | 96% | 95.5% |
CBD | This study | 85.9% | 78.6% | 98.9% | 73.0% |
Infrared fence and multiple pressure mats | [38] | N/A | N/A | 92.3% | 99.4% |
Thermal array and ultrasonic sensor | [40] | 95.5% | 93.8% | 71.4% | 99.3% |
RFID | [31] | N/A | N/A | 93.8% | 90.8% |
Kinect | [41] # | 98.8% | N/A | N/A | N/A |
eNightLog | This study * | 99.0% | 99.2% | 98.8% | 99.2% |