Skip to main content
. 2021 Jan 31;14(3):655. doi: 10.3390/ma14030655

Table 3.

Determined physicochemical parameters of real galvanic wastewater.

Parameter Unit Result *
pH 3.4 ± 0.1
Electrical conductivity, EC µS/cm 25,800 ± 1290
Salinity as NaCl mg/L 12,850 ± 640
Complexing compounds as EDTA mg/L 180 ± 28
Copper (Cu) mg/L 59.0 ± 5.90
Cadmium (Cd) mg/L 4.50 ± 0.45
Zink (Zn) mg/L 22.70 ± 2.27

* Parameter value ± the measurement uncertainty for an extension factor k = 2; for pH, uncertainty was ±0.1%; for electrocoagulation (EC) and salinity, measurement uncertainty was ±5%; for complexing compounds, Cu, Cd, Zn was ±10%.