Skip to main content
. 2021 Feb 1;21(3):972. doi: 10.3390/s21030972

Table 4.

LSTM-autoencoders precision metrics.

Historical Maintenance Records Precision Metrics
Equipment State Dates Initial Intermediate Bad
Initial 2019-12-24 T 01:01:49–2019-12-25 T 02:42:55 79.86% 79.95% 79.90%
Intermediate 2020-01-10 T 00:38:54–2020-01-10 T 23:01:24 79.06% 80.12% 79.58%
Bad 2020-01-13 T 00:05:47–2020-01-13 T 23:38:20 78.10% 78.34% 78.43%
Initial 2020-02-20 T 00:46:49–2020-02-21 T 22:38:45 88.03% 88.07% 88.09%
Intermediate 2020-02-25 T 01:20:54–2020-02-26 T 03:46:30 71.47% 74.08% 72.07%
Bad 2020-03-01 T 01:53:56–2020-03-01 T 21:37:48 65.46% 65.78% 66.02%
Initial 2020-03-02 T 01:00:14–2020-03-02 T 23:15:53 74.35% 74.97% 75.29%
Intermediate 2020-03-08 T 00:10:24–2020-03-08 T 22:46:33 72.94% 73.49% 73.34%
Bad 2020-03-16 T 09:13:47–2020-03-16 T 21:37:48 72.21% 77.22% 77.26%