Table 3.

Overall performance values for Alvarado score, ultrasound, CT, and diagnostic algorithm

Measurement Alvarado-score > 7 (n = 183) Ultrasonography (n = 181) CT scan (n = 36) Diagnostic algorithm (n = 183)
% 95% CI % 95% CI % 95% CI % 95% CI
Sensitivity 73.9 61–84 58.2 35–62 100 81–100 100 95–100
Specificity 88.1 81–93 97.3 92–99 100 82–100 96.6 92–99
PPV 77.4 65–87 90.0 73–98 100 81–100 94.2 86–98
NPV 85.9 78–92 78.9 71–85 100 82–100 100 97–100
Accuracy 82.3 76–87 80.9 74–87 100 92–100 97.8 95–99

PPV positive predictive value, NPV negative predictive value