Table 2.
NIOSH and BioSpot Aerosol Samples Collected From Double-Occupancy Airborne-Infection Isolation Rooms of COVID-19 Patients
Room | No. of Patients | Day of Illness | Clinical Ct Valuesa | SARS-CoV-2 RNA Copies per m–3 Air |
Aerosol Particle Size | Sampler |
---|---|---|---|---|---|---|
1 | 2 | 3; 4 | 23; 32.5 | ND ND |
<1 μm, 1–4 μm, >4 μm, <4.34 µm |
NIOSHb
BioSpotc |
2 | 2 | 5; 4 | 19.6; 15 | 40.48 908.02 |
<1 μm 1-4 μm |
NIOSHb |
1,083.1 469.9 |
>4 μm <4.34 µm |
BioSpotc |
Note. ND, none detected; PCR, polymerase chain reaction; Ct, cycle threshold; NIOSH, National Institute for Occupational Safety and Health.
PCR cycle threshold values from patient respiratory samples collected within 72 h of room sampling.
Six 840-L samples pooled and analyzed together (5,040 L air total). Size fractionation retained.
One 3,840-L sample.