Table 3.
Binary logistic regression analysis of the association between risk factors and ISR.
| Variables | cOR | 95% CI | P-value | aOR | 95% CI | P-value |
|---|---|---|---|---|---|---|
| Length of stenosis | 1.034 | 0.887–1.204 | 0.671 | 1.018 | 0.849–1.220 | 0.847 |
| Length of stent | 0.872 | 0.761–0.998 | 0.046 | 0.816 | 0.699–0.953 | 0.010 |
| Stent type | 3.500 | 1.180–10.378 | 0.024 | 5.748 | 1.533–21.546 | 0.009 |
| Anesthesia mode | 4.301 | 1.561–11.885 | 0.005 | 6.000 | 1.693–21.262 | 0.006 |
ISR, in-stenting restenosis; cOR, crude odds ratio; aOR, adjust odds ratio.