Skip to main content
. Author manuscript; available in PMC: 2021 Sep 1.
Published in final edited form as: Crit Care Med. 2020 Sep;48(9):e791–e798. doi: 10.1097/CCM.0000000000004468

Table 2:

Sensitivity, specificity, positive, and negative predictive values for Text and CUI-based models. Bolded lines are referenced in text.

Model Threshold Sensitivity Specificity Positive Predictive Value Negative Predictive Value
CUI-based model ≥ 0.1 98% 16% 50% 91%
≥ 0.2 88% 41% 57% 80%
≥ 0.3 71% 57% 59% 69%
≥ 0.4 57% 75% 66% 67%
≥ 0.5 46% 80% 67% 63%
≥ 0.6 37% 88% 73% 62%
≥ 0.7 24% 94% 79% 59%
≥ 0.8 8% 97% 75% 55%
≥ 0.9 1% 100% 100% 54%
Text-based model ≥ 0.1 95% 32% 55% 87%
≥ 0.2 72% 72% 69% 75%
≥ 0.3 42% 89% 77% 64%
≥ 0.4 19% 96% 81% 58%
≥ 0.5 8% 98% 75% 55%
≥ 0.6 3% 100% 100% 54%