Skip to main content
. 2020 Dec 31;11(4):e2. doi: 10.5037/jomr.2020.11402

Table 3.

Mesial and distal MBL (intragroup) around implants placed in posterior maxillary pristine bone (spontaneously healed posterior maxillary extraction sockets) by means of osteotome-mediated sinus floor elevation and in posterior maxillary extraction sockets grafted by 4 to 5 months, (intergroup) in function of elapsed time since functional loading (intragroup)

Site Bone Implant MBL (mm)

1 year 2 years 3 years 4 years 5 years





Mean (SD) Mean (SD) Mean (SD) Mean (SD) Mean (SD)
Mesial Pristine Short length 0.07 (0.12) 0.11 (0.21) 0.18 (0.32) 0.21 (0.28) 0.33 (0.51)

Standard length 0.06 (0.14) 0.12 (0.19) 0.16 (0.38) 0.23 (0.34) 0.30 (0.44)

Grafted Short length 0.09 (0.13) 0.12 (0.19) 0.17 (0.28) 0.22 (0.33) 0.34 (0.47)

Standard length 0.07 (0.11) 0.1 (0.22) 0.19 (0.31) 0.23 (0.43) 0.33 (0.49)

Distal Pristine Short length 0.08 (0.11) 0.13 (0.22) 0.17 (0.38) 0.24 (0.38) 0.37 (0.44)

Standard length 0.07 (0.12) 0.11 (0.2) 0.19 (0.42) 0.22 (0.44) 0.35 (0.45)

Grafted Short length 0.09 (0.13) 0.12 (0.17) 0.18 (0.25) 0.23 (0.47) 0.32 (0.26)

Standard length 0.06 (0.11) 0.14 (0.21) 0.2 (0.51) 0.25 (0.33) 0.31 (0.39)

MBL = marginal bone loss; SD = standard deviation.