Skip to main content
. 2020 Sep 4;31(3):1236–1244. doi: 10.1007/s00330-020-07172-2

Table 2.

Concordance between delayed-contrast cardiac computed tomography and transesophageal echocardiography for the detection of left atrial appendage thrombus

CCT TEE (n = 260), n (%)
Thrombus No thrombus
Angiographic phase
Filling defect 10 (4) 53 (20)
No filling defect 0 197 (76)
1-min delay
Filling defect 10 (4) 5 (2)
No filling defect 0 245 (94)
p value with previous timing < 0.001
3-min delay
Filling defect 10 (4) 2 (1)
No filling defect 0 248 (95)
p value with previous timing 0.437
6-min delay
Filling defect 10 (4) 0
No filling defect 0 250 (96)

p value with previous timing 0.663