Table 2.
Mobile monitoring instrumentation.
| Measurement platform | Measurement parameter | Sampling approach | Instrument make/model | Sample type and frequency |
|---|---|---|---|---|
| EV | CO2 | Non-dispersive infrared (NDIR) gas analyzer | LiCOR/Model 820 | Continuous, 1-second averages |
| NO2 | Cavity Attenuated Phase Shift (CAPS) | Aerodyne Research, Inc./CAPS NO2 Monitor | ||
| Particle number concentration (size range 5.6–560 nm, 32 channels) | Engine Exhaust Particle Sizer | TSI, Inc./Model 3090 | ||
| Longitude and Latitude | GPS | Crescent R100/Hemisphere GPS | ||
| Video | Webcam | Logitech | ||
| BC | Single-channel Aethalometer | Magee Scientific/AE-42 | ||
| SUV | NO2, nitric oxide (NO) | CAPS | Aerodyne Research, Inc./CAPS NO2 Monitor | Continuous, 1-second averages |
| Particle number concentration (size range 5.6–560 nm, 32 channels) | Engine Exhaust Particle Sizer | TSI, Inc./Model 3090 | ||
| BC | Micro-Aethalometer | Magee Scientific/AE-51 | ||
| CO2 | NDIR | LiCOR/Model 820 | ||
| Video | Webcam | Logitech |