Parameters of the TDCR used for the case study.

Parameter Value
Segment length L (m) 50103
Disk radius rd (m) 8103
Backbone diameter (m) 0.8103
Young modulus E (Pa) 2.111011
Quadratic moment I (m4) 2.011014
Stiffness EI (N.m2) 4.2103
Position of tendons in (R)j frame
OjPj,1, OjPj,3 [0rd0]
OjPj,2, OjPj,4 [0rd0]