Skip to main content
. 2021 Feb 16;11:3932. doi: 10.1038/s41598-021-83141-z

Table 3.

Differences in predictive accuracy related to certain versus uncertain sample predictions in the validation set (24 biopsy samples, 7 patients).

Uncertainty threshold Number of samples (n) Overall accuracy Sensitivity/specificity (%/%)
Entire pooled cohort 24 67% 43/76
p < 0.05 (certain) 18 78% 75/79
p > 0.05 (uncertain) 6 33% 0/67

Shown are the differences in predictive performance of the transductive learning GP model for the entire pooled validation cohort and also when stratifying the sample predictions with high certainty (low p values) versus low certainty (high p values) at various p value thresholds.