Skip to main content
. 2020 Dec 9;34(2):330–344. doi: 10.1021/acs.chemrestox.0c00253

Table 8. Class-Wise Performance of Binary Model Distinguishing Weak to Moderate Sensitizers from Strong to Extreme Sensitizers on the Test Set.

ε class validity efficiency
0.10 weak to moderate sensitizers 0.92 0.47
strong to extreme sensitizers 1.00 0.37
0.20 weak to moderate sensitizers 0.86 0.71
strong to extreme sensitizers 0.95 0.68
0.30 weak to moderate sensitizers 0.74 0.97
strong to extreme sensitizers 0.79 1.00