Skip to main content
. 2021 Feb 10;41(6):1251–1264. doi: 10.1523/JNEUROSCI.2503-20.2020

Table 1.

Parameter sets for modeled ionic channels

gmax (nS) Vrev (mV) Activation/Inactivation Exponential α/β F k (1/ms) V (mV) s (mV)
Na 25,385 50 Activation 3 α 1 1.0 −40 −10
β 2 4.0 −65 −18
Inactivation 1 α 2 0.07 −65 −20
β 3 1.0 −35 −10
Kd 615 −100 Activation 4 α 1 0.1 −55 −10
β 2 0.125 −65 −80
Kv3 3,000 −100 Activation 1 α 1 −0.12166 4.18371 −6.42606
β 2 0.015857 0 −25.4834