Table 1.

Comparison of cryptococcal antigen detection and blood culture techniques.

Culture positive (%) Culture negative (%) Total
LFA positive 15 (25.4) 44 (74.6) 59
LFA negative 1 (0.4) 240 (99.6) 241
Total 16 (5.3) 284 (94.7) 300

Sensitivity: 93.75%, specificity: 84.51%, likelihood ratio =6.051, χ2=58.71, P<0.0001.