Skip to main content
. Author manuscript; available in PMC: 2021 Feb 17.
Published in final edited form as: IEEE Access. 2019 Jun 5;7:75058–75066. doi: 10.1109/access.2019.2921027

TABLE 2.

SSD results compared with MICCIA endoscopic vision challenge.

TP FP FN Prec Rec F1 F2
SSD-ResNet50 167 63 41 72.6 80.3 76.3 78.6
SSD-InceptionV3 167 60 41 73.6 80.3 76.8 78.9
SSD-VGG16 158 96 50 62.2 75.9 68.4 72.7
YOLOV3 120 37 88 76.4 57.7 65.8 60.7
CUMED 144 55 64 72.3 69.2 70.7 69.8
CVC-CLINIC 102 920 106 10.0 49.0 16.5 27.5
ETIS-LARIB 103 1373 105 6.9 49.5 12.2 22.3
OUS 131 57 77 69.7 63.0 66.1 64.2
PLS 119 630 89 15.8 57.2 24.9 37.6
SNU 20 176 188 10.2 9.6 9.9 9.7
UNS-UCLAN 110 226 98 32.7 52.8 40.4 47.1
Faster RCNN [27] 167 26 41 86.5 80.3 83.3 81.5