Skip to main content
. 2021 Feb 9;2021:8819780. doi: 10.1155/2021/8819780

Table 2.

Temperature of the IR emitter.

Drying air temperature (°C) Drying air velocity (m∙s−1) IR emitter temperature (°C)
1000 W 750 W 500 W
30 1.5
1.5
1.5
543.30 ± 8.73k 396.16 ± 5.39g 233.10 ± 2.61c
35 548.21 ± 7.36k 407.60 ± 5.23h 232.19 ± 3.1bc
40 566.51 ± 3.6l 426.42 ± 6.09i 237.59 ± 2.05c

30 2.5
2.5
2.5
523.98 ± 4.47j 346.65 ± 9.85d 220.63 ± 1.46a
35 524.49 ± 5.32j 361.69 ± 9.12e 219.03 ± 2.62a
40 527.21 ± 6.169j 374.10 ± 12.17f 222.80 ± 2.62ab

Means within a column followed by the same letter are not significantly different according to Fisher's unprotected least significant difference test (p < 0.05).