Skip to main content
. 2021 Feb 2;7(2):e06151. doi: 10.1016/j.heliyon.2021.e06151

Table 1.

Operating conditions of the primary WHB.

Shell Side Tube Side
Type of fluid Sec. Reformer Effluent Gas Boiler Water (BW)
Design Pressure, MPa 3.6 11.8
Operating Pressure, MPa 3.07 10.55
Operating Temperature, °C 995 (inlet)/525 (outlet) 314
Tube Material SA-179 (inner tube)
SA-209 Gr T1a (outer tube)
Cap Material SA-204 Gr B
Tube Size, mm 25.4 OD x 1.65 thickness, 8235–8845 Length (inner tube)
50.8 OD x 3.4 thickness, 7027–7637 Length (outer tube)
Number of Tubes, ea 421