Table 1.
Operating conditions of the primary WHB.
| Shell Side | Tube Side | |
|---|---|---|
| Type of fluid | Sec. Reformer Effluent Gas | Boiler Water (BW) |
| Design Pressure, MPa | 3.6 | 11.8 |
| Operating Pressure, MPa | 3.07 | 10.55 |
| Operating Temperature, °C | 995 (inlet)/525 (outlet) | 314 |
| Tube Material | SA-179 (inner tube) SA-209 Gr T1a (outer tube) |
|
| Cap Material | SA-204 Gr B | |
| Tube Size, mm | 25.4 OD x 1.65 thickness, 8235–8845 Length (inner tube) 50.8 OD x 3.4 thickness, 7027–7637 Length (outer tube) |
|
| Number of Tubes, ea | 421 | |