Table 14.
Correction factors to account for TVAC chamber window transmission, calculated from observations of a 116-patch Macbeth Color Target imaged at uniform illumination both with and without the TVAC chamber window in place on May 1, 2019 (see Table 3)
Filter number | Effective center wavelength (nm) | Red | Green | Blue |
---|---|---|---|---|
Effective window transmission ±1σ uncertainty | ||||
L0 | 530 | 0.941±0.0072 | 0.948±0.0077 | 0.946±0.007 |
L1 | 802 | 0.92±0.0049 | 0.92±0.0053 | 0.921±0.0056 |
L2 | 754 | 0.921±0.0052 | 0.923±0.0056 | 0.922±0.0053 |
L3 | 678 | 0.926±0.0053 | 0.948±0.006 | 0.937±0.0052 |
L4 | 605 | 0.938±0.008 | 0.938±0.0073 | 0.938±0.0076 |
L5 | 528 | 0.937±0.0038 | 0.937±0.0039 | 0.938±0.0039 |
L6 | 441 | 0.938±0.0087 | 0.938±0.0087 | 0.938±0.0087 |
L7 | 590 | -±- | -±- | -±- |
R0 | 530 | 0.942±0.0049 | 0.949±0.007 | 0.953±0.013 |
R1 | 802 | 0.919±0.0045 | 0.921±0.0055 | 0.921±0.0053 |
R2 | 866 | 0.907±0.0049 | 0.907±0.0045 | 0.907±0.0052 |
R3 | 910 | 0.898±0.005 | 0.899±0.0037 | 0.899±0.0041 |
R4 | 939 | 0.901±0.0035 | 0.901±0.0037 | 0.903±0.0053 |
R5 | 978 | 0.898±0.0041 | 0.898±0.0035 | 0.9±0.0048 |
R6 | 1012 | 0.898±0.0045 | 0.898±0.0046 | 0.899±0.0051 |
R7 | 880 | -±- | -±- | -±- |