Skip to main content
. 2020 Jun 24;29(3):1650–1654. doi: 10.1044/2020_AJSLP-20-00020

Table 3.

Intrarater reliability for sequential and randomized coding of all swallow kinematic events.

Swallow kinematic event ICC PEA
Bolus crosses mandible 1.00 98%
Onset of hyoid movement 1.00 97%
Maximal hyoid displacement 1.00 89%
Offset of hyoid movement 1.00 77%
Laryngeal vestibular closure 1.00 66%
Laryngeal vestibular re-opening 1.00 97%
UES opening 1.00 99%
UES closure 1.00 89%

Note. ICC = intraclass correlation coefficient; PEA = percent exact agreement; UES = upper esophageal sphincter.