Skip to main content
. 2021 Feb 25;9:e00185. doi: 10.1016/j.ohx.2021.e00185

Table 1.

First testing session. Fit testing results for the Aria QR + mask (medium/large) using the coated PLA adapter, sealed with putty, with the 3M 2091 filters, and the fit testing method drilling the mask (Fig. 5).

Mask configuration 3M 6800 full face respirator Snorkel mask duct tape Snorkel mask no modifications Snorkel mask mouth cover removed
Normal breathing 297,913 44,910 18,511 1123
Deep breathing 288,127 40,394 27,612 1412
Head side to side 442,017 63,628 38,360 1541
Head up and down 349,546 66,749 63,259 1234
Talking 266,729 21,200 7933 1953
Bending over 326,150 12,676 7534 929
Normal breathing 454,406 76,511 16,065 593
Overall fit factor 333,867 32,281 15,448 1105
Fit Test* Pass Pass Pass Pass
*

OSHA fit factor passing value is 500 or greater.