Table 3. Comparison of the baseline, one-month, and one-year follow-up values measured by transthoracic echocardiography.

LVEDV, left ventricular end-diastolic volume; LVESV, left ventricular end-systolic volume; LVEF, left ventricular ejection fraction; PASP, pulmonary artery systolic pressure; RA, Right atrium; RV, right ventricle; RVFAC, RV fractional area change; TAPSE, tricuspid annular plane systolic excursion

P<0.001 comparison of the baseline, one-month, and one-year follow-up values

  Baseline One-month One-year
LVEDV, mL 184 ±36.1 182 ±44.6 161 ±47.6
LVESV, mL 122 ±44.2 120 ±51.9 97 ±38.1
LVEF (%) Teicholz 27.4 ±6.0 27.9 ±5.5 30.9 ±5.8
PASP, mmHg 46.23 ±16.93 45.84 ±15.24 45.75 ±14.69
RVFAC, % 36.38 ±4.54 36.57 ±4.36 37.19 ±4.91
TAPSE, mm 15.38 ±2.35 15.65 ±2.69 15.80 ±3.03
Myocardial performance index 0.48 ±0.03 0.49 ±0.05 0.50 ±0.06
E peak, cm/s 43.34 ±5.81 43.50 ±6.08 43.30 ±5.92
A peak, cm/s 45.88 ±4.21 45.53 ±4.72 45.66 ±4.41
Deceleration time, ms 246.05 ±18.70 245.17 ±18.13 241.84 ±20.07