Table 4.

Respiratory Mechanics and Blood Oxygenation under Mechanical Ventilation

Variable Open-lung Ventilation (n = 43) Control Ventilation (n = 43) P Value
Regional lung compliance,* mean ± SD, arbitrary units per cm H2O
 Anesthesia onset
  Ventral 176.0 ± 73.4 163.7 ± 115.6 0.639
  Dorsal 123.6 ± 76.6 73.1 ± 56.6 0.005
 End of surgery
  Ventral 185.9 ± 96.9 167.4 ± 121.1 0.535
  Dorsal 133.4 ± 111.9 89.5 ± 70.3 0.088
Respiratory system compliance, mean ± SD, ml per cm H2O
 Anesthesia onset
  Dynamic 67.1 ± 25.0 49.6 ± 24.3 0.015
  Static 61.6 ± 16.8 45.5 ± 17.3 0.002
 End of surgery
  Dynamic 48.3 ± 22.6 46.5 ± 29.9 0.286
  Static 53.9 ± 13.8 49.7 ± 18.7 0.119
Pao2/Fio2 ratio, mean ± SD, mmHg
 Anesthesia onset 441 ± 129 311 ± 131 0.001
 End of surgery 374 ± 103 273 ± 97 < 0.001
Alveolar arterial gradient, mean ± SD, mmHg
 End of surgery 166 ± 81 172 ± 70 0.843
 Extubation time 97 ± 48 142 ± 57 0.026
*

Measured with pulmonary electrical impedance tomography. Data come from n = 86 for respiratory system compliance and arterial oxygen tension (Pao2)/fraction of inspired oxygen (Fio2) ratio, n = 56 for regional lung compliance, and n = 30 for alveolar arterial gradient.